ตรวจข้อสอบ > ปาณัสม์ พงษ์ประดิษฐ์ > ชีววิทยาเชิงวิทยาศาสตร์การแพทย์ | Biology in Medical Science > Part 2 > ตรวจ

ใช้เวลาสอบ 24 นาที

Back

# คำถาม คำตอบ ถูก / ผิด สาเหตุ/ขยายความ ทฤษฎีหลักคิด/อ้างอิงในการตอบ คะแนนเต็ม ให้คะแนน
1


What is the primary function of AI in the medical imaging industry?

To improve diagnostic accuracy and patient outcomes

the AI is use to support clinical decision and workflow Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

2


Which of the following is a key benefit of AI in radiology noted in the article?

Acts as a second medical opinion

the AI analyze the patient result and produce a medical opinion to compare with the radiologist opinion Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 2 methodology 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

3


What does AI literacy refer to according to the article?

Understanding and knowledge of AI technology

the study of AI as written in the article Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . Abstract Result 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

4


Which factor is NOT listed as influencing the acceptability of AI among healthcare professionals?

The color of the AI machines

the color doesn't influence the acceptability Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 3.8. Factors influencing healthcare professional acceptability of AI in medical imaging domains 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

5


What role does social influence play in AI acceptability in healthcare according to the article?

Shapes how AI is marketed

social influence will control how AI is displayed to the public whether positively or negatively Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 3.8. Factors influencing healthcare professional acceptability of AI in medical imaging domains 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

6


What is a perceived threat regarding AI usage in healthcare settings?

Concerns about replacing healthcare professionals

healthcare professional are concern that it will take their jobs Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 3.8. Factors influencing healthcare professional acceptability of AI in medical imaging domains 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

7


According to the article, what is essential for increasing AI acceptability among medical professionals?

Designing human-centred AI systems

with the AI being Human-Centred the concerns about jobs and false diagnostic will mostly be solve. Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 4.8. Future work and direction 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

8


What does the 'system usage' category of AI acceptability factors include according to the article?

Factors like value proposition and integration with workflows

it contain mostly about the aspect about working and efficiency Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 3.8. Factors influencing healthcare professional acceptability of AI in medical imaging domains 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

9


How does ethicality impact AI acceptability among healthcare professionals?

Affects views on AI based on compatibility with professional values

ethicality focus on medical profession and patient data privacy Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 3.8. Factors influencing healthcare professional acceptability of AI in medical imaging domains 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

10


What methodological approach did the article emphasize for future AI acceptability studies?

Considering user experience and system integration deeply

the user trust and essential to appropriately integrate AI in the the medical network Understanding the factors influencing acceptability of AI in medical imaging domains among healthcare professionals: A scoping review from ScienceDirect . section 2. Methodology 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

11


What is the primary objective of using human embryonic stem cells in treating Parkinson’s disease?

To replace lost dopamine neurons.

in hope of replacing the DA neuron stem cell is considered to be a perfect replacement Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD Introduction 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

12


Which animal was used to test the STEM-PD product for safety and efficacy?

Rats

rats was use to test for adverse effect and tumor formation Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD Manufacturing and quality control of STEM-PD 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

13


What was the duration of the preclinical safety study in rats mentioned in the article?

9 months

the time was mention in the study highlight Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . Hight light 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

14


What is the name of the clinical trial phase mentioned for STEM-PD?

Phase I/IIa

tested on a single arm on a human Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . Introduction 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

15


How is the STEM-PD product manufactured?

Under GMP-compliant conditions

using MCB manufactured from GMP grade line Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD .Manufacturing and quality control of STEM-PD 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

16


According to the article, what confirmed the safety of the STEM-PD product in rats?

There were no adverse effects or tumor formation.

no adverse effect were found including no tumor formation Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . Hight light 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

17


What key finding was noted in the efficacy study of STEM-PD in rats?

Transplanted cells reversed motor deficits in rats.

the stem cell reverse the amphetamine effect on the rat Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . STEM-PD grafts are rich in DA neurons, innervate the host brain, and reverse amphetamine-induced rotations in rats 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

18


What specific markers were used to assess the purity of the STEM-PD batch?

FOXA2 and OTX2

written in the invivo and batch to batch comparison Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . STEM-PD shows robust and reproducible in vivo efficacy in batch-to-batch comparison 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

19


What role do growth factors like FGF8b and SHH play in the manufacturing process of STEM-PD?

They are used in cell patterning for specific neural fates.

it tell the cell what shape and how they should arrange themself Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . Manufacturing and quality control of STEM-PD 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

20


What was a key outcome measured in the preclinical trials for efficacy in rats?

Recovery of motor function

the rats regain the motor function that was lost from amphetamine-induced rotation Preclinical quality, safety, and efficacy of a human embryonic stem cell-derived product for the treatment of Parkinson’s disease, STEM-PD . STEM-PD grafts are rich in DA neurons, innervate the host brain, and reverse amphetamine-induced rotations in rats 7

-.50 -.25 +.25 เต็ม 0 -35% +30% +35%

ผลคะแนน 108.75 เต็ม 140

แท๊ก หลักคิด
แท๊ก อธิบาย
แท๊ก ภาษา